logo
russian english german
 

IVK MicroTEK-09

Purpose

 

IVK MicroTEK-09 is aimed for accounting of crude and commercial oil (GOST R 8.595, GOST R 8.615, MI 2693) at the facilities of oil and petroleum industries.

 

MicroTEK-09  is used for quality and quantity metering of crude and commercial oil for routine and fiscal metering. It can provide metering of up to 5 lines and data processing from oil quality control unit.

 

Features 

 
  • designed to be located to 19 inch stand
  • in-built spark proof circuits, not generating extra error, providing the required accuracy of metering
  • hook up of field equipment with no auxiliary equipment
  •  

    Functions

     
    • receiving and processing frequency, impulse, analogue and discrete signals within metering limits of measuring transducers
    • automatic control, indication and signaling about ultimate values of metered parameters
    • calculation, indication and transfer of recorded parameters into telemechanics system through RS-485  ModBus RTU, Ethernet ModBus  TCP/IP interfaces
    • mode for metrological features control and calibration of volume and weight meters as per reference meter
    • mode for metrological features control and calibration of volume and weight meters as per calibration unit in compliance with MI 1974, MI 2463
    • operation with field sensors through RS-485  Modbus RTU digital interface and HART protocol
    • generating oil receipt report, oil data sheet and metering devices changes log
     

    Basic Features

     

    Parameter

    Value

    Measuring channels parameters 

     Standardized current signal measuring channel: 

       Measuring range, mA

    4...20

       Maximum number of channels in IVK, pcs

    40

     Temperature sensor signal measuring channel:

       Temperature range, °С:

     

           - Copper thermoresistance
           (NSC TSM-50, TSM-100 as per GOST 8.625-2006)

    from -100 to +100

           - Copper thermoresistance
           (NSC TSM-50, TSM-100 as per GOST 8.625-2006)

    from -100 to +100

       Maximum number of channels in IVK, pcs

    10

     Pulse-frequency signal measuring channel: 

       Measuring range, Hz

    1..10 000

       Signal amplitude range, V

    0,06…24

       Maximum number of channels in IVK, pcs

    8

     Metrologic Parameters 

     Limits for absolute permissible error of metering:

       Standardized current signal, mA

    ±0,015

       Thermal converter signal, °С

     ±0,05

     Limits for relative permissible error of metering: 

       Pulse quantity, %

    ±0,025 

       Input frequency, %

    ±0,002

       Input signal frequency metering channel, %

    ±0,01

       Ratio of pulse quantity per time interval, %

    ±0,01

     Limits for relative permissible error to convert input electric signals into actual values:

       Metering crude and commercial oil volume, %

    ±0,025

       Metering crude and commercial oil volume, %

    ±0,05

       Coefficient for volume flow meter, %

    ±0,025

       Coefficient for weight flow meter, %

    ±0,04

     Technical Parameters

    AC voltage, V

    110...250

    Operation temperature ranges, °С

    from +1 to +50

    Dimensions (width x depth x height), mm

    483х132х348

    Weight, kg

    12

    Fastening

     19'' stand

    Explosion protection marking

     [Ex ia] IIC