GSM-05 External Connection Diagram

 

GSM-03 External Connection Diagram (Phoenix Contact)

 

GSM-03 External Connection Diagram (OKW)

       
 
 

EXAMPLES OF GSM APPLICATION

 

Gas contamination control system based on GSM-05 for polymerization unit for polypropylene production                      

 

Basic Functions

 
  • Continuous monitoring of hazardous concentrations of vapors of flammable gases and fluids and their mixtures of IIA, IIB, IIC categories and Т1, Т2, Т3, Т4 groups as per GOST 51330.5-99, GOST Р51330.11-99 in explosion hazardous areas of premises of all classes and outside facilities and open spaces as per Chapter 7.3 of PUE, using thermal chemical technique with temperature ranges from minus 60 to plus 50 °С
  • Mandatory recording of gas contamination accidents
  • Generating two alarm thresholds for each line, alarm level for each is to be setup by the user within ranges from 0 to 50% of lower inflammability level
  • Generating analogue signals (4-20) mA proportional to the gas concentration value in % of lower inflammability level The load connected to the current output of the alarm unit can not exceed 350 Ohm.
  • Issue of control digital signals into external circuit for each control point, blocking up the power supply to the equipment in case the detector is switched off or issue of signals about the state of the detector into external circuit which will provide the switch on of emergency ventilation reaching a certain level of concentration (Threshold 1, Threshold 2).

Parameters of Output Signals

 
  • Failure
  • Output type  

     Clean contact

    Supply voltage, V 

      0 - 30 

    Current

    Direct

    Load current by Ucom ≤ 30 V, not exceeding, mA   

      100 

     
  • Threshold 1, Threshold 2
  • Two way contact

    Two positions

    Supply voltage, V 

       0 - 250

    Current 

     Direct/alternating

    Load current by Ucom ≤ 250 V, not exceeding, A

     1 (alternating current)

    Load current by Ucom ≤ 30 V, not exceeding, A

      1 (direct current)

     

     
     
     
     

    Gas contamination control system based on GSM-03 gas detectors within computing unit IVK MicroTEK for oil metering system (SIKN)

     

    GSM Functions within IVK MicroTEK

     

    In case of actuating of fire alarm or gas contamination control system:

    - When reaching Threshold 1of lower inflammability level - switching on the alarm and ventilation
    - When reaching Threshold 2 of lower inflammability level - switching on emergency alarm and disconnecting all power consumers within SIKN.

    Note - parameters for Threshold 1 and Threshold 2 are setup through the software within the range from 0 to 50% NKPV.